Kitchen Remodel Cost Calculator

Electrical scope

How many circuits the new kitchen needs, and whether your panel has room

A kitchen is the most electrically dense room in a house, and the electrical scope is almost never in the first quote. It arrives later as a change order, because the moment the walls open the job stops being "reuse what is there" and becomes "bring this room up to what is currently enforced".

Circuits, devices and whether the panel can take them

The counters
ft
ft

Set to what your jurisdiction enforces. Spacing rules differ by adopted edition and by local amendment.

The appliances
A
A
A
A

A 240-volt appliance takes two breaker spaces, not one.

The panel
A
A

Derived new circuits

9

Needing 10 breaker spaces, against 4 free.

Counter receptacles 7 derived from run length and spacing
Receptacles in total 9
Breaker space shortfall 6
Connected kitchen load 79.0 A
Projected demand 87.5 A existing plus kitchen at half coincidence
Service headroom 12.5 A

Panel verdict An older breaker panel may physically accept the circuits, but several brands from that era are no longer supplied with new breakers and some are refused outright by inspectors. Have the brand identified before you plan around it.

  • Confirm the panel brand and whether replacement breakers are still listed for it.
  • The kitchen needs 10 breaker spaces and 4 are free. You are 6 short.
  • Projected demand of 88 amps leaves 13 amps of headroom on a 100-amp service. A service upgrade involves the utility and their calendar, not just your electrician.
  • Island receptacles are the requirement that changed most recently and the one most likely to be handled differently by two inspectors in the same county. Ask before the counter is fabricated, because the answer can put a hole in it.

The circuit schedule this kitchen derives

CircuitPolesRatingWhy it exists
Small-appliance branch circuit 1120 AServes the countertop receptacles. These are the circuits a toaster and a kettle fight over.
Small-appliance branch circuit 2120 AServes the countertop receptacles. These are the circuits a toaster and a kettle fight over.
Electric range250 AA 240-volt appliance takes two breaker spaces and a four-conductor run, not one.
Dishwasher115 ARuns on its own circuit so a motor start does not trip the counters.
Garbage disposal115 ARuns on its own circuit so a motor start does not trip the counters.
Refrigerator115 ARuns on its own circuit so a motor start does not trip the counters.
Microwave115 ARuns on its own circuit so a motor start does not trip the counters.
Lighting circuit 1115 AKitchen lighting is kept off the small-appliance circuits so a tripped breaker does not leave you in the dark.
Lighting circuit 2115 AKitchen lighting is kept off the small-appliance circuits so a tripped breaker does not leave you in the dark.

Take this schedule to your electrician and ask which of these already exist, which can be reused, and which are new home runs. The answer to that question is most of the electrical price, and it is a twenty-minute conversation rather than a survey.

What an hour of this work is worth, and why the quotes differ

This page derives scope rather than price, because the price of a circuit is set by your county and the scope is set by your kitchen. The one part of it the United States government does measure is what the person pulling the wire is paid, and it is worth seeing the line that figure was read out of.

Bureau of Labor Statistics series, as returned by its public API · retrieved 2026-08-06

Hourly median wage for Electricians in All Industries in the United States 30.38 (2025 Annual)

U.S. Bureau of Labor Statistics, Occupational Employment and Wage Statistics (May 2025) — BLS public API, electrician median hourly wage

What it means for your kitchen That is a wage paid to an electrician, not a rate charged to you: the gap between the two covers payroll tax, insurance, the van, the licence, the unbillable hours and the profit, and on the labour page it is an editable multiplier of ours rather than anything the agency published.

The electrical line is the least predictable on any kitchen bid

Of the six trades a kitchen employs, electricians carry the widest published pay spread — 69.9% from the twenty-fifth percentile to the seventy-fifth. That is measured within one occupation, in one country, in the same year. It means two electrical quotes for the identical circuit schedule above can differ substantially without either bidder being unreasonable, and it is why the useful question is how many circuits are new home runs rather than why one number is bigger.

What the wage series says nothing about

It covers the person, not the parts and not the paperwork. A panel, breakers, AFCI and GFCI devices, wire, boxes and a permit are all priced separately, and in a kitchen with a service upgrade the utility appears on the invoice as well, at a figure the electrician does not set. When an electrical quote surprises you, the surprise is more often in that list than in the hourly rate.

It also says nothing about how long any of this takes, which is the other half of every labour number. The hours behind a circuit are our own estimate and are disclosed as one:

When the panel becomes the project

Spaces, not amps, is usually the binding constraint

People assume a service upgrade is about running out of amps. Far more often the panel simply runs out of physical spaces, and a kitchen adds five to eight of them at once. Tandem breakers recover some spaces in panels that permit them; a subpanel recovers a lot; a full replacement recovers all of them and brings the utility into the schedule.

Old panels that inspectors will not pass

Several panel brands from the mid twentieth century are no longer supplied with listed breakers, and some are refused outright. If your panel is one of them, that is not a kitchen cost — it is a house cost the kitchen happened to uncover, and it has to be scheduled before rough-in rather than discovered during it.

The utility is on the critical path, and does not care about yours

A service upgrade needs a utility appointment for the disconnect and reconnect, and that appointment is scheduled on their calendar. Two to six weeks is common and it is not negotiable by paying more. If the panel is being replaced, get the utility booked the day the decision is made.

Sources for this page

Two wage series, both national, both retrieved by machine on the date shown. Nothing on this page cites a code provision, and the reason is on the methodology page: we could not read the code text from its publisher, so every code-driven quantity here is a control you set from what your own jurisdiction enforces rather than a constant we printed.

  1. U.S. Bureau of Labor Statistics, Occupational Employment and Wage Statistics (May 2025)Median hourly wage, electricians — the midpoint of the band quoted above.BLS public API — series OEUN000000000000047211108 · retrieved 2026-08-06
  2. U.S. Bureau of Labor Statistics, Occupational Employment and Wage Statistics (May 2025)Twenty-fifth percentile hourly wage, electricians — the bottom of the spread cited in this section.BLS public API — series OEUN000000000000047211107 · retrieved 2026-08-06
  3. U.S. Bureau of Labor Statistics, Occupational Employment and Wage Statistics (May 2025)Seventy-fifth percentile hourly wage, electricians — the top of that spread.BLS public API — series OEUN000000000000047211109 · retrieved 2026-08-06